Key Information

WCM1L

Pole: 2P, 3P, 3P+N,4P

Voltage: AC230V/400V

kA: 35-75kA

Inm(A): 100,125, 250, 400, 800

In(A): 10A-800A

General

WCM1L series residual current protection moulded case circuit breaker (RCCB for short) is one new breaker researched and developed by advanced international design and manufacture technology of the company. The rated insulation voltage 800V, applies AC50Hz, rated operation voltage 400V, rated operation current upto 800A for infrequent switch of the line and infrequent start of the motor. RCCB has protection functions to overload, short circuit and under voltage, to protect the line and power device from deamge, also make protection to the fire caused by grounding fault at long time that undetected under over current.

RCCB is divided into type M (higher breaking), and type H (very high breaking), has features of smal volume, high breaking, short flashover, vibration resistance, etc.,

Main technical parameters

ModelWCM1L-125WCM1L-250WCM1L-400WCM1L-800
Frame current Inm (A)125250400800
Rated current In (A)(10), 16, 20, 25, 32, 40, 50, 63, 80, 100, 125100, 125,140, 160, 180, 200, 225, 250225, 250, 315, 350, 400400, 500, 630, 700, 800
Pole (P)2342343434
Rated insulation voltage Ui (V)AC800
Rated operation voltage Ue (V)AC400
Rated impulse withstand voltage Uimp (V)8000800080008000
Flashover distance (mm)≯50≯50≯100>100
Breaking capacity rankMH
MH
M
M
Ultimate short circuit breaking capacity Icu (kA)AC 400V35
503550
5050
Operation short circuit breaking capacity Ics (kA)AC 400V22
352250
3535
Rated residual operation current IΔn (mA)Non-delayed type100/300/500-
Delayed type100/300/500300/500/1000
Rated residual non-action current IΔno (mA)IΔn/2
Rated residual short circuit connecting (breaking capacity IΔm (kA)Icu/4
Operation performance (times)Power-on1500100010001000
Power-off8500700040004000
Shunt release>>>>>>>>
Under voltage release>>>>>>>>
Leakage alarm unit modular>>>>>>>>
Auxiliary contact>>>>>>>>
Alarm contact>>>>>>>>
Motor-driven operation mechanism>>>>>>>>
Rotating handle operation mechanism>>>>>>>>


Notes: 1. It includes vertical and horizontal installation of ultimate breaking and flashover distance;
            2. Three poles circuit breaker of this series connects with three phase loading, of which can not be with neutral line, otherwise the circuit breaker will make fault operation;
           3. Three poles circuit breaker of this series connects with three phase loading, phase line at left pole, neutral line at right pole not the middle pole.

Contact Us

Contact: westhomes

Phone: 0097142210039/0097142297823

Tel: 05666-16680

E-mail: westhomeshhz@gmail.com

Add: Show Room No.1-Sabkha UAE SHOWROOM

主站蜘蛛池模板: 巴楚县| 新疆| 邵阳市| 邹城市| 大同市| 额尔古纳市| 剑阁县| 澄江县| 高雄县| 庄河市| 七台河市| 阳新县| 龙山县| 泸州市| 温泉县| 乐亭县| 库伦旗| 双鸭山市| 阳曲县| 内乡县| 许昌市| 邹平县| 沂源县| 屏南县| 九江县| 乐安县| 江山市| 睢宁县| 灵川县| 峡江县| 虹口区| 钟山县| 建瓯市| 望奎县| 宜黄县| 牟定县| 中方县| 邓州市| 子洲县| 汝城县| 西丰县|